LOG IN / HELP

<<< BACK TO JOB

Midway-Sunset: 02946634

Enter:
(1) Well metadata for each well, if missing.
(2) Run metadata for each run.
(3) Log curve descriptions for each run.
(4) Temperature and resistivity observations for each run.

This task is closed and unheld.

See DOGGR well records.

Well construction

Name
Spud date 1972-03-13
Abandon date
Borehole orientation Directional
Measured depth 1670.000
True vertical depth 1669.800
Tperf 875.000
Bperf 1670.000
Water geochem
No well data
Glog unavailable
Notes

Run headers

Service company GO INTERNATIONAL GO INTERNATIONAL SCHLUMBERGER
Tool INDUCTION ELECTRICAL LOG INDUCTION ELECTRICAL LOG DUAL INDUCTION/SP/GAMMA RAY
Date 1972-03-14 1972-03-14 1994-12-28
Run number ONE TWO 1
Driller depth 1565.000 1595.000 1670.000
Logger depth 1565.000 1595.000 1670.000
Log bottom 1564.000 1594.000 1664.000
Log top 20.000 1550.000 865.000
Casing size 11.750 11.750 7.000
Bit size 10.625 10.625 6.250
Mud type CLAY BASE CLAY BASE GEL/DRILLPAC
Mud density 68.00 68.00 8.90
Mud visc (plastic) 44.00 44.00
Mud visc (funnel) 60.00
Mud ph 7.50
Mud fluid loss 5.00 5.00 6.80
Sample source FLOWLINE FLOWLINE FLOWLINE
Circulation stopped time 17:45:00
Logger on bottom time 19:30:00
Time since circulation 2.000 2.000
Operating rig time
Notes FLUID LOSS IN C3

G-log curves

1972-03-14 ONE
40" INDUCTION
6 COIL 40" INDUCTION CONDUCTIVITY
A-16"-M SHORT NORMAL
SPONTANEOUS POTENTIAL
1972-03-14 TWO
40" INDUCTION
6 COIL 40" INDUCTION CONDUCTIVITY
SHORT NORMAL A-16"-M -18'8"-N-∞-B
SPONTANEOUS POTENTIAL
1994-12-28 1
GAMMA RAY (GR)
IL-DEEP CONDUCTIVITY (CILD)
IL-DEEP RESISTIVITY (ILD)
IL-Medium Resistivity (ILM)
SFL UNAVERAGED (SFLU)
SP (SP)
TENSION (TENS)

Temperature and mud resistivity observations

1972-03-14 ONE
Rm = 3.600 Ωm @ 100.000 °F (MRT, 1565.000 ft)
Rm = 4.100 Ωm @ 87.000 °F
Rmc = 4.400 Ωm @ 87.000 °F
Rmf = 3.000 Ωm @ 87.000 °F
1972-03-14 TWO
Rm = 3.600 Ωm @ 100.000 °F (MRT, 1595.000 ft)
Rm = 4.100 Ωm @ 92.000 °F
Rmc = 4.400 Ωm @ 92.000 °F
Rmf = 3.000 Ωm @ 92.000 °F
1994-12-28 1
Rm = 2.987 Ωm @ 145.000 °F (MRT, 1670.000 ft)
Rmf = 2.177 Ωm @ 145.000 °F (MRT, 1670.000 ft)
Rm = 4.940 Ωm @ 85.000 °F
Rmc = 4.520 Ωm @ 49.000 °F
Rmf = 6.260 Ωm @ 46.000 °F

Change log


59837 2019-02-11 11:04 ashley CLOSED, UNHANDED
59837 2019-02-11 11:03 ashley EDITED RUN 1 (Dec. 28, 1994)
59837 2019-02-11 10:59 ashley EDITED RUN TWO (March 14, 1972)
59837 2019-02-11 10:58 ashley EDITED RUN ONE (March 14, 1972)
59837 2019-02-11 10:56 ashley EDITED WELL METADATA
59837 2019-02-11 10:54 ashley TAKEN
59837 2018-08-09 13:28 e.haugen TASK CREATED
20850 2018-08-06 08:05 sgainer CLOSED, UNHANDED
20850 2018-08-06 08:04 sgainer EDITED RUN TWO (March 14, 1972)
20850 2018-08-06 08:03 sgainer ADDED RUN TWO (March 14, 1972)
20850 2018-08-06 08:02 sgainer EDITED RUN 1 (Dec. 28, 1994)
20850 2018-08-06 08:01 sgainer ADDED RUN 1 (Dec. 28, 1994)
20850 2018-08-06 07:58 sgainer EDITED RUN ONE (March 14, 1972)
20850 2018-08-06 07:57 sgainer ADDED RUN ONE (March 14, 1972)
20850 2018-08-06 07:56 sgainer EDITED WELL METADATA
20850 2018-08-06 07:55 sgainer TAKEN
20850 2018-01-04 20:36 whdc TASK CREATED

Well versions and related tasks